Electrical Connection
Connecting the supply cord to the electrical mains:
A double pole mains switch must be installed between
the appliance and the mains. The double pole mains
switch must have a minimum of 3mm of space between
the contacts, be sized to the load and comply with current
regulations (the switch must not be able to disconnect
the earth conductor).
The supply cord should conform to BS6004 conductor
size 4mm2 and must be positioned so that no part of it
reaches a temperature of 50°C higher than room tem-
perature.
Before making the connection, make sure that:
the limiter switch (fuse) and the residual wiring can
support the appliance load (see the rating plate).
the mains system is properly earthed in compliance
with current regulations and provisions.
there is easy access to the socket or the double pole
mains switch after the appliance is installed.
IMPORTANT:
If the hob is installed above a built-in oven, the electrical
connection for the hob must be independent of that for
the oven, both for safety reasons and to facilitate the
removal of the oven for maintenance, repair etc.
Voltage and frequency of power supply:
230-240V
50-60Hz
7700W
Electrical Connections:
12345
To connect the supply cord, proceed as follows:
- Loosen the screws on the wire clamp "V", as well as
the screws for the contacts.
- Insert the wires beneath the contact screws, as shown
in the diagram and tighten them.
- Fasten the cord with the appropriate wire clamp and
close the cover.
Electrical Connection
THIS APPLIANCE MUST BE EARTHED.
The installation procedure must be carried out by a
qualified electrician.
The electrical safety of this appliance is guaranteed only
if the appliance is correctly earthed in compliance with
the standards of electrical safety.
The manufacturer can under no circumstances be
considered responsible for any damage that might occur
due to incorrect earthing of the hob.
The electric hob is not supplied with a power supply
cord because the type of cord used depends on the type
of electrical connection (see following diagram). Open
the terminal box, following the instructions illustrated in
the diagram below:
IMPORTANT POINTS:
Your hob is supplied with a special connection cable.
If ever the cable is damaged it should be replaced by an
authorised service engineer only.
Disconnect the hob form the electrical supply before any
work is carried out.
••••
L N Fuse 25A
2
1
1
2
3
4
5
V
Seitenansicht 8
1 2 3 4 5 6 7 8 9 10 11 12